ANDEEN-HAGERLING |
|
AH 2700A
50 Hz-20 kHz
Ultra-precision
Capacitance Bridge
|
 |
| The
World’s Most Accurate 50Hz-20kHz Capacitance/Loss1
Bridge |
The AH 2700A offers unparalleled stability,
resolution, linearity and accuracy in a multi-frequency capacitance/loss1
bridge (whether manual or automatic). Its numerous state-of-the-art features
make it an exceptionally user-friendly instrument. The precision of the
AH 2700A is creating new applications in calibration, science, and production
in a wide range of fields.
Frequencies: 50,
60, 80, 100, 120, 160, 200, 240, 320, 400, 500, 600, 800 Hz and 1.0, 1.2,
1.6, 2.0, 2.4, 3.2, 4.0, 5.0, 6.0, 8.0, 10, 12, 16 and 20 kHz
Selected Precision Specifications
| Frequency |
Accuracy |
Stability |
Temperature
Coefficient |
Resolution |
| kHz |
ppm |
ppm/year |
ppm/°C |
aF |
ppm |
| 0.1 |
±9 |
±<1.9 |
±0.07 |
16 |
0.8 |
| 1 |
±5 |
±<1.0 |
±0.035 |
0.8 |
0.16 |
| 10 |
±11 |
±<1.9 |
±0.07 |
2.4 |
0.5 |
Outstanding Features
-
Measures extremely low loss down to a dissipation factor of 1.5x10-8
tan d, a conductance of 3x10-7
nanosiemens or a resistance up to 1.7x106
gigohms
-
As little as 0.4 second required for full precision measurements
and as little as 30 ms required for repeated measurements on the
same sample
-
Fast analog output has a frequency response of 3 kHz at 3 dB down
-
Negative capacitance and loss ranges measure negative values to
allow for unusual samples or three terminal networks
-
Commutation (test signal reversal) to minimize external power line
or other periodic signal pickup
-
Three terminal BNC connections minimize connector costs and number
of cables
-
IEEE-488 GPIB and IEEE-1174 serial interfaces included; remote device
can act as controller or logger
-
Programmability can eliminate the need for an external controller
-
Large, variable-brightness displays having 8 digits for capacitance
and loss and 5 digits for frequency
-
Deviation measurements of capacitance, loss or both
-
Zero correction of test fixture capacitance and loss
-
External DC bias up to ±100 volts
-
External trigger capability
-
NIST or NPL traceable calibration
-
Autoranging
-
Automatic internal calibration
-
Self-test diagnostics on power-up and by command
-
Three year warranty
[1]
The term “loss” is used to refer to the component of the impedance which
is 90° out of phase with respect to the capacitive component. The AH
2700A can report loss in units of conductance, dissipation factor, series
or parallel resistance, or loss vector.
| For additional
information regarding the AH 2700A, possible applications, the location
of your nearest sales representative, or ordering information: |
| Call: 440-349-0370 |
Fax: 440-349-0359 |
| E-mail:
info@andeen-hagerling.com |
 |
ANDEEN-HAGERLING,
INC.
31200 Bainbridge Road
Cleveland, Ohio 44139-2231 U.S.A. |
Home | AH 2700A Bridge |
AH 2550A Bridge |
AH
2500A Bridge | AH 1100/11A Standard | AH
DCOAX Cable | AH TTA1 Test Adapter | Reader Response Form